Images are representations only.

TIDALFLUX 2300 F Electromagnetic Flow Sensor

Brand: Krohne
The TIDALFLUX 2000 flow sensor with integrated and non-contact capacitive level measuring system provides accurate flow measurement in partially filled pipes. 

TIDALFLUX is designed to measure reliably between 10% and 100% of the pipe cross section. 

The integrated level sensors in the liner are in no contact with the liquid and are therefore insensitive against fat and oil floating on the surface.
Features
  • For partially filled pipes in the water and wastewater industry
  • Broad diameter range up to DN1600 / 64"
  • High abrasion resistance and chemical resistance
  • Measurement possible between 10% and 100% filling
  • Electrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface
  • Complete factory calibration - no on-site calibration necessary
The TIDALFLUX 2000 flow sensor with integrated and non-contact capacitive level measuring system provides accurate flow measurement in partially filled pipes. 

TIDALFLUX is designed to measure reliably between 10% and 100% of the pipe cross section. 

The integrated level sensors in the liner are in no contact with the liquid and are therefore insensitive against fat and oil floating on the surface.
Features
  • For partially filled pipes in the water and wastewater industry
  • Broad diameter range up to DN1600 / 64"
  • High abrasion resistance and chemical resistance
  • Measurement possible between 10% and 100% filling
  • Electrodes for flow measurement are below 10% filling level, therefore no blind folding by fat and oil floating on the water surface
  • Complete factory calibration - no on-site calibration necessary

Specifications

Brand

Accuracy

  • Fully Filled: ≤ 0.5 % of mV + 5 mm/sec/0.2”/s
  • Fully Filled: ≤ 1 % of mV
  • Partly Filled: ≤ 1 % of Full Scale

Ambient Temperature Range

  • ATEX Zone 1: -20° to 65° C (-4° to 149° F)
  • Non-ATEX: -40° to 65° C (-40° to 149° F)

Applications

  • Biological & Chemical Wastewater
  • Electrically Conductive Fluids
  • For Partially Filled Pipes Instead of Expensive Siphon Tube Constructions
  • Surface Water
  • Water & Wastewater

Approvals & Certifications

  • ATEX Ex Zone 1
  • AWWA - AWWA (Class D): DN 700 to 1600 / 28 to 48” ≤ 284 psi (19.58 bar, 1,958 kPa)
  • CE
  • EMC Directive: 2004/108/EC, Harmonized Standard: EN 61326-1: 2006
  • IECEx Zone 1
  • LVD Directive: 2006/95/EC, Harmonized Standard: EN 61010: 2001
  • NAMUR NE21/04
  • PED Directive: 97/23/EC

Approvals & Certifications

  • IEC 68-2-6 (Vibration), IEC 68-2-34 (Random Vibration), IEC 68-2-27 (Shock)

Cable Entry

  • 1/2” NPT
  • M16 x 1.5
  • M20 x 1.5

Cable Length

  • Signal Cable: Max.

Communication

  • HART
  • Modbus

Connection Material

  • Polyurethane Coated Die Cast Aluminum
  • Stainless Steel

Consumption

  • Power Consumption: 22 VA AC

Enclosure, Body Material

  • Sheet Steel

Environmental Protection

  • IP66
  • IP67
  • IP68
  • NEMA 4
  • NEMA 4X
  • NEMA 6
  • NEMA 6P

Flange Material

  • Carbon Steel, Polyurethane Coated

Flange Size - 10” (DN 250)

  • 10” (DN 250) - 150# ASME
  • 10” (DN 250) - JIS 10K
  • 10” (DN 250) - JIS 20K
  • 10” (DN 250) - PN 10

Flange Size - 12” (DN 300)

  • 12” (DN 300) - 150# ASME
  • 12” (DN 300) - JIS 10K
  • 12” (DN 300) - JIS 20K
  • 12” (DN 300) - PN 10

Flange Size - 14” (DN 350)

  • 14” (DN 350) - 150# ASME
  • 14” (DN 350) - JIS 10K
  • 14” (DN 350) - JIS 20K
  • 14” (DN 350) - PN 10

Flange Size - 16” (DN 400)

  • 16” (DN 400) - 150# ASME
  • 16” (DN 400) - JIS 10K
  • 16” (DN 400) - JIS 20K
  • 16” (DN 400) - PN 10

Flange Size - 18” (DN 450)

  • 18” (DN 450) - 150# ASME
  • 18” (DN 450) - JIS 10K
  • 18” (DN 450) - JIS 20K
  • 18” (DN 450) - PN 10

Flange Size - 20” (DN 500)

  • 20” (DN 500) - 150# ASME
  • 20” (DN 500) - JIS 10K
  • 20” (DN 500) - JIS 20K
  • 20” (DN 500) - PN 10

Flange Size - 24” (DN 600)

  • 24” (DN 600) - 150# ASME
  • 24” (DN 600) - JIS 10K
  • 24” (DN 600) - JIS 20K
  • 24” (DN 600) - PN 10

Flange Size - 28” (DN 700)

  • 28” (DN 700) - 150# ASME
  • 28” (DN 700) - JIS 10K
  • 28” (DN 700) - JIS 20K
  • 28” (DN 700) - PN 10

Flange Size - 32” (DN 800)

  • 32” (DN 800) - 150# ASME
  • 32” (DN 800) - JIS 10K
  • 32” (DN 800) - JIS 20K
  • 32” (DN 800) - PN 10

Flange Size - 36” (DN 900)

  • 36” (DN 900) - 150# ASME
  • 36” (DN 900) - JIS 10K
  • 36” (DN 900) - JIS 20K
  • 36” (DN 900) - PN 10

Flange Size - 40” (DN 1000)

  • 40” (DN 1000) - 150# ASME
  • 40” (DN 1000) - JIS 10K
  • 40” (DN 1000) - JIS 20K
  • 40” (DN 1000) - PN 10

Flange Size - 48” (DN 1200)

  • 48” (DN 1200) - 150# ASME
  • 48” (DN 1200) - 300# ASME
  • 48” (DN 1200) - JIS 10K
  • 48” (DN 1200) - JIS 20K
  • 48” (DN 1200) - PN 6

Flange Size - 56” (DN 1400)

  • 56” (DN 1400) - 150# ASME
  • 56” (DN 1400) - 300# ASME
  • 56” (DN 1400) - JIS 10K
  • 56” (DN 1400) - JIS 20K
  • 56” (DN 1400) - PN 6

Flange Size - 64” (DN 1600)

  • 64” (DN 1600) - 150# ASME
  • 64” (DN 1600) - 300# ASME
  • 64” (DN 1600) - JIS 10K
  • 64” (DN 1600) - JIS 20K
  • 64” (DN 1600) - PN 6

Flange Size - 8” (DN 200)

  • 8” (DN 200) - 150# ASME
  • 8” (DN 200) - JIS 10K
  • 8” (DN 200) - JIS 20K
  • 8” (DN 200) - PN 10

Flange Type

  • Raised Face (RF)

Materials of Construction

  • Liner: Polyurethane
  • Measuring Electrodes: Hastelloy C
  • Remote Converter, Measuring Tube (Austenitic): Stainless Steel

Measuring Range

  • -12 to 12 m/sec / -40 to 40 ft/sec
  • Electrical Conductivity: 50 to 5,000 μS/cm

Media

  • Conductive Liquids
  • Fluids

Mounting

  • 2” Pipe with Clamps
  • Wall Mounted

Mounting Position

  • Downwards

Operating Pressure - Sensor

  • psi: 14.5 (kPa: 100, bar: 1)

Power Supply

  • 100-230 Vac, (-15 % / 10 %), 50/60 Hz
  • 24 Vac/dc (AC: -15 % / 10 %, 50/60 Hz, DC: -25 % / 30 %)

Process Temperature

  • 0° to 60° C (32° to 140° F)

Ring Material

  • Grounding Rings: Stainless Steel

Storage Temperature

  • -50° to 70° C (-58° to 158° F)