Calculated Accuracy: The gross at standard temperature to gross volume ratio, excluding the accuracy of fluid temperature measurement, exactly matches the proper volume correction factor of ASTM-D-1250-04 over the fluid temperature range of -58° F to 302° F (-50° C to 150° C)
Temperature Measurement Accuracy: Fluid temperature is measured to within ± 0.72° F (± 0.4° C) over the fluid temperature range of -328° F to 572° F (-200° C to 300° C). Fluid temperature is measured to within ± 0.45° F (± 0.25° C) over the fluid temperature range of 32° F to 572° F (0° C to 300° C).
Stability: 0.1° F (0.06° C)/year
Flow Totalizing: Within one pulse of input frequency
Electromagnetic Compatibility (EMC)
EMC Directive 2014/30/EU
EN 61326-1: Electrical equipment for measurement, control and laboratory use
Environment
Ambient Operating Temperature: -40° F to 140° F (-40° C to 60° C)