Images are representations only.

MAR 10/50/90 Electric Actuator

Brand: RCS Actuators
The percentage of time the electric motor is energized vs. the time it is at rest, in reversing duty and with the actuator running at it’s rated load maximum published torque.

Standard Modulating Duty Rating
  • 12 motor starts (corrections) per minute
  • At the rated duty cycle for that model
  • With the speed of operation a minimum of 15 seconds for 90° or slower
  • With positioning accuracy of (+/-) 1% of total span
Isolation Relays
To operate multiple actuators in parallel from a single signal requires isolating relays in the field wiring. Consult factory.
The percentage of time the electric motor is energized vs. the time it is at rest, in reversing duty and with the actuator running at it’s rated load maximum published torque.

Standard Modulating Duty Rating
  • 12 motor starts (corrections) per minute
  • At the rated duty cycle for that model
  • With the speed of operation a minimum of 15 seconds for 90° or slower
  • With positioning accuracy of (+/-) 1% of total span
Isolation Relays
To operate multiple actuators in parallel from a single signal requires isolating relays in the field wiring. Consult factory.
Models matching criteria: 26
  • Voltage - 12/24 VDC
  • Model - DCR 50
  • No Load Speed of Operation - 0.7 second/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 7.5 RPM (6.2 RPM)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 2 second/90° (2.5 seconds/90°)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 10 seconds/90° (12 seconds/90°)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 90
  • No Load Speed of Operation - 7 RPM
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 90
  • No Load Speed of Operation - 5.6 seconds/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 90
  • Speed of Operation 60 Hz (50 Hz) - 5 seconds/90° (6 seconds/90°)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 30 RPM (N/A)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 60 seconds/90° (70 seconds/90°)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 90
  • Speed of Operation 60 Hz (50 Hz) - 15 seconds/90° (17.5 seconds/90°)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 60 seconds/90° (70 seconds/90°)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 10
  • No Load Speed of Operation - 6.4 seconds/90°
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 50
  • No Load Speed of Operation - 21 RPM
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 50
  • No Load Speed of Operation - 42 seconds/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 30 RPM (N/A)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 10
  • No Load Speed of Operation - 0.6 second/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 90
  • Speed of Operation 60 Hz (50 Hz) - 3 RPM (2.5 RPM)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 2 second/90° (2.5 seconds/90°)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 50
  • No Load Speed of Operation - 21 seconds/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 30 seconds/90° (35 seconds/90°)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 90
  • No Load Speed of Operation - 2.2 second/90°
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 10 seconds/90° (12 seconds/90°)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 10
  • No Load Speed of Operation - 25 RPM
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 50
  • Speed of Operation 60 Hz (50 Hz) - 30 seconds/90° (35 seconds/90°)
Out of Stock
  • Voltage - 115 and 230 VAC, 1 Phase, 50/60 Hz
  • Model - MAR 10
  • Speed of Operation 60 Hz (50 Hz) - 7.5 RPM (6.2 RPM)
Out of Stock
  • Voltage - 12/24 VDC
  • Model - DCR 50
  • No Load Speed of Operation - 5.6 seconds/90°
Out of Stock

Specifications

Certifications & Approvals

  • CSA NRTL/C

Temperature Range

  • Standard: -40° to +150° F (-40° to +65° C)
  • Optional: -60° to +120° F (-50° to +48° C)

Voltage

  • 115 Vac, 1-Phase, 50/60 Hz
  • 230 Vac, 1-Phase, 50/60 Hz
  • 24 Vac, 1-Phase, 50/60 Hz
  • 12 Vdc/ 24 Vdc

Torque

  • 120 to 1,000 lb-in (13.5 to 112 Nm)

Speed

  • 0.5 to 60 seconds for 90° Revolution
  • 7.5 & 30 RPM for Multi-turns

Applications

For on/off and modulating control of
  • Part turn ball, butterfly or plug valves
  • Rotary dampers
  • Rotating equipment
  • Multi-turn valve types

Documentation