Description
Tank gauging is essential for the assessment of tank contents, tank inventory control and tank farm management.
Honeywell's Enraf® Portfolio of High-end Radar and Servo Tank Gauges help in accurate level gauging for refineries, tank terminals and petrochemical industries.
The tank gauges are suitable for custody transfer as well as inventory control and are designed to be used in SIL-3 loops to prevent spillage.
What Is It?
Honeywell’s portfolio of radar tank gauges include:
- SmartRadar FlexLine suitable for highly accurate level measurement on large bulk storage tanks.
- SmartRadar FlexLine combines new software algorithms with Honeywell Enraf’s planar antennae technology to provide precision levels demanded for custody transfer accuracy.
- Free Space Antenna portfolio for SmartRadar FlexLine starts from smaller 6” antenna to 8” antenna, designed to address all installation needs on cone roof tanks. The planar antennas for stilling well covers stilling well application ranging from 6’ to 24’ diameter stilling wells.
How Does It Work?
In the most challenging circumstances such as dome roofs and bad stilling wells, SmartRadar FlexLine maintains its ultra-high performance level on a wide range of applications and various tank conditions. The Enhanced Performance Signal processing enables the radar tank gauge to provide an accurate level reading even in difficult applications (close to the tank shell) and prevents the need for a costly stilling well.
The FlexLine radar tank gauge has been certified for use in SIL-2 and SIL-3 applications by the TÜV which allows it to be used in overfill protection applications. Additional diagnostics have been added to detect hardware failures, while a 2004D voting algorithm will detect, report and isolate failures on the boards without interrupting the loading or unloading of a tank.
What Problems Does It Solve?
The FlexLine offers high flexibility that can be used for dedicated tank applications such as independent overfill protection, floating roof monitoring, rim fire detection, roof immersion compensation, etc. The FlexLine wireless option reduces the cost for wiring infrastructure and increases flexibility as various instruments can be added to the network without adding cables.
The radar tank gauge is also certified for use in custody transfer applications.
Configure
Specifications
Specifications
Certifications & Approvals
- SIL
- ATEX
- FM
- CSA
- INMETRO
- TÜV
- GOST-R
- PESO (India)
- NEPSI
Measuring Range
- Up to 75 m (246 ft)
Measuring Solution
- 0.1 mm (0.001”)
Update Time
- 0.1 s
Process Temperature
- -200° to 250° C (-328° to 482° F)
Maximum Process Pressure
- Horn Antennas: Up to 40 bar / 4 MPa (580 psi)
- Planar (PAT) Antennas: Up to 6 bar / 0.6 MPa (87 psi)
Ambient Temperature
- -40° to 65° C (-40° to 149° F)
Storage Temperature
- -50° to 75° C (-58° to 167° F)
Instrument Housing
- Cast Aluminum Alloy According to EN 1706, AA A356 EN 1706, AC-AlSi7Mg0.3
Finish Aluminum Parts
- Hard Anodized According to MIL A8625-E Type III
Cover
- Aluminum, Coating: Polyurethane
O-Ring
- NBR 70
Antenna Material
- Ball Valve (Optional with Horn Antenna) Stainless Steel CF8M (Mat no.: 1.4408)
- High Pressure Horn Antennas: SS AISI 316 (Mat. no.: 1.4401) and PTFE (In High Pressure Tank Separator)
- Planar (PAT) Antennas: SS AISI 316 (Mat. no.: 1.4401) and FEP
Overfill Protection
- DIBt WHG, Corcon BVBA
SIL Certification
- SIL 3 (Redundant Configuration, HFT=1), Sccording to IEC 61508 & IEC 61511
- TÜV Certified for SIL 2 (Single Configuration, HFT= 0)
Ingress Protection
- NEMA 4X
- IP67
- IP66
Power Supply
- 24-65 Vdc (+10 % to -15 %)
- Autoselect 65-240 Vac (+10 % to -15 %) 50/60 Hz
Power Rating
- Typical 15 W, Max. 23 W with All Options
Communication
- RS-232, RS-485 GPU Protocol
- HART Slave - Multidrop and/or 4-20 mA