Images are representations only.

Touchscreen Gasket - Item 6

Price
$165.00 USD
Stock
In Stock

Specifications

Accuracy

  • Calculated Accuracy: The gross at standard temperature to gross volume ratio, excluding the accuracy of fluid temperature measurement, exactly matches the proper volume correction factor of ASTM-D-1250-04 over the fluid temperature range of -58° F to 302° F (-50° C to 150° C)
  • Temperature Measurement Accuracy: Fluid temperature is measured to within ± 0.72° F (± 0.4° C) over the fluid temperature range of -328° F to 572° F (-200° C to 300° C). Fluid temperature is measured to within ± 0.45° F (± 0.25° C) over the fluid temperature range of 32° F to 572° F (0° C to 300° C).
  • Stability: 0.1° F (0.06° C)/year
  • Flow Totalizing: Within one pulse of input frequency

Electromagnetic Compatibility (EMC)

  • EMC Directive 2014/30/EU
  • EN 61326-1: Electrical equipment for measurement, control and laboratory use

Environment

  • Ambient Operating Temperature: -40° F to 140° F (-40° C to 60° C)
  • Humidity: 5 to 95 % with condensation