Bidirectional, High Resolution (1,050 pulses/bbl)

Price
Request a Quote
Stock
In Stock
Description
Note 2:  Due to an engineering enhancement, when replacing a high resolution rotor assembly or internal parts kit in a meter manufactured prior to July of 1990 (Date Code KG), it may be necessary to replace the housing also to achieve proper repeatability. Contact the Parts Operation with any questions
Note 2:  Due to an engineering enhancement, when replacing a high resolution rotor assembly or internal parts kit in a meter manufactured prior to July of 1990 (Date Code KG), it may be necessary to replace the housing also to achieve proper repeatability. Contact the Parts Operation with any questions

Specifications

Linearity

  • ± 0.15 % linearity over normal flow range
  • ± 0.10 % linearity over 5:1 flow range
  • ± 0.07 % linearity over 5:1 flow range

Repeatability

  • Per API MPMS or OIML R-117-1

Overspeed

  • 130 % of maximum flow rate for 5 % duty cycle

End Connections

  • Class 150, 300, 600, ASME B16.5, 125-250 AARH finish raised face (RF) flanges
  • Consult factory for higher working pressure or other types of flanges

Weights and Measures

  • PTB Issued OIML R117-1 Test Report
  • European Union: MID - Measuring Instrument Directive, MID 2014/32/EU
  • Consult Factory for others

Pressure Safety Requirements

  • European Union: PED - Pressure Equipment Directive, PED 2014/68/EU
  • CRN - Canadian Registration Number - Consult Factory

Electromagnetic Compatibility

  • European Union: EMC Compliance by Council Directive EMC Directive 2014/30/EU
  • EN 61326-1: Electrical equipment for measurement, controland laboratory use