Description
The Rosemount 1195 Integral Orifice Primary Element is engineered to facilitate highly accurate flow measurement in small line sizes: 0.5 to 1.5 in or 15 to 40 mm.
The primary element is provided in a meter run for easy installation and is suitable for flow measurements of gas, liquid or steam.
This product utilizes a self-centering orifice plate to prevent installation error and it can be ordered as a completely assembled flowmeter or as an assembled-to product.
Features- Primary Element Integrated in a Meter Run for Ease of Installation
- Available to Order Pre-assembled with a Transmitter for a Complete Flow Assembly
- Suitable for Small Line Sizes 0.5 to 1.5 in / 15 to 40 mm for Optimal Flow Measurement Accuracy and Repeatability
- Self-centering Orifice Plate Prevents Installation Error to Ensure Best-possible Performance
- Directly Mounts to Any Rosemount DP Transmitter and Offers a Range of Process Connections for Application Flexibility
Specifications
Specifications
Brand
Approvals & Certifications
- CRN
- PED
Bore Size
- 0.066” to 1.184” (1.68 to 30.07 mm)
Enclosure, Body Material
- 316 Stainless Steel
- 316L Stainless Steel
- Alloy 400, C-276
Media
- Liquids & Gases
- Steam
Process Connection - Other
- Pipe Ends: Beveled
Process Connection Style
- NPT Threaded
- RF & RTJ Flange: ANSI Class 150, 300, 600, 900, DIN PN 16, 40, 100
Size
- Line Size: 0.5” to 1.5” (15 to 40 mm)
Temperature Range
- -100° to 285° C (-148° to 554° F)
Wetted Materials
- 316 Stainless Steel