Description
The Rosemount 5600 Level Transmitter allows for advanced processing and is suitable for high temperature and high pressure applications as well as for measuring solids.
The strength of a 4-wire device is its high sensitivity and its ability to detect weak radar echoes in challenging process environments. The built-in diagnostics are able to detect disturbing objects and identify the true echo.
Features- Suitable for most applications due to a wide selection of materials, process connections, antenna styles, and accessories
- Easy connection with adjustable power supply, 24 Vdc or 110-240 Vac, 0 to 60 Hz
- Interchangeable transmitter heads and antennas
Specifications
Specifications
Brand
Approvals & Certifications
- ATEX
- CSA
- EAC
- FCC
- FM
- IECEx
Approvals & Certifications
- TÜV Tested & WHG Approved for Overfill Prevention
Communication
- 4-20 mA HART
- Modbus
Cover Material
- PTFE
Flange Material
- 316L Stainless Steel
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150#
- 4” (DN 100) - PN 16
Flange Size - 6” (DN 150)
- 6” (DN 150) - 150#
- 6” (DN 150) - PN 16
Flange Size - 8” (DN 200)
- 8” (DN 200) - 150#
- 8” (DN 200) - PN 16
Frequency
- Operating Frequency: FMCW 10 GHz
O-Ring Material
- Ethylene Propylene (EPDM)
- Kalrez 6375 Perfluoroelastomer
- Nitrile Butadiene (NBR)
- Viton Fluoroelastomer
Operating Pressure
- psi: 0 to 798 (kPa: 0 to 5,500, bar: 0 to 55)
Operating Temperature
- -40° to 400° C (-40° to 750° F)
Output
- 4-20 mA
Power Supply
- 110-240 Vac 0-60 Hz
- 24 Vdc
Pressure Range
- bar: 0 to 55
- kPa: 0 to 5,500
- psi: 0 to 798
Tri-Clamp Connection
- 3” Tri-Clamp
- 4” Tri-Clamp
- 6” Tri-Clamp
- 8” Tri-Clamp
Documentation
Documentation
Product Manuals
Certificates & Approvals
Drawings & Schematics
- Type 1 Drawing: Rosemount 2210 Display Unit: Electrical Installation, Remote Version 2D PDF pdf 66 KB
- Type 1 Drawing: Rosemount 2210 Display Unit: Electrical Installation, Remote with Temp Inputs 2D PDF pdf 87 KB
- Type 1 Drawing: Rosemount 2210 Display Unit: Mech. Installation 2D PDF pdf 50 KB
- Type 1 Drawing: Rosemount 5600 Level Gauge: Bridle Installation Page 1, 2D PDF pdf 94 KB
- Type 1 Drawing: Rosemount 5600 Level Gauge: Bridle Installation Page 2, 2D PDF pdf 48 KB
- Type 1 Drawing: Rosemount 5600 Level Gauge: Rod Antenna 2D PDF pdf 82 KB
- Type 1 Drawing: Rosemount 5600 Level Gauge: Still Pipe Antenna Page 1 2D PDF pdf 87 KB