Description
Gain confidence with the reliable performance of the Rosemount 2051L Level Transmitter, a transmitter that provides level measurements with a variety of process connections, materials and output protocols.
This transmitter is safety certified, and allows for Tuned-System™ Level assembly and direct mounting.
Engineered with a Local Operator Interface - LOI, this device offers easy, on-site commissioning.
Features- Designed with a Variety of Process Connections, Materials and Output Protocols to Meet Diverse Application Requirements
- Tuned-system Level Assembly and Direct Mounting Produce Optimal Performance for Level Applications
- SIL 2/3 Certified to IEC 61508 - via 3rd Party, and Prior-use Certificate of FMEDA Data for Safety Installations
- Local Operator Interface - LOI for Simple, Local Commissioning On-site without the Use of Extra Tools or Training
- Optimized Seal System Construction Ensures a Quality Measurement in Harsh Process Conditions
Configure
Specifications
Specifications
Brand
Accuracy
- ± 0.075 % of Span
Alarm
- Custom Alarm & Saturation Signal Levels
- NAMUR Alarm & Saturation Signal Levels
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Applications
- Marine & Offshore Applications
- Vacuum
Approvals & Certifications
- ATEX
- CCOE
- CSA
- FM
- GOST
- IEC Ex
- INMETRO
- NEPSI
- TIIS
Conduit Connection
- A Size Mini, 4-Pin Male Connector (minifast)
- M12, 4-Pin, Male Connector (eurofast)
Configuration
- 4-20 mA HART
- FOUNDATION Fieldbus Protocols
- Low-Power, 1-5 Vdc with Digital Signal based on HART Protocol
- PROFIBUS PA Protocol
- Wireless Protocols
Damping Adjustment
- User Configurable from 0 to 60 seconds
Diaphragm Material
- 316L Stainless Steel
- Hastelloy C-276
- Tantalum
Display
- LCD Display
- LCD Display with Local Operator Interface
- None
Drain, Vent Valves & Plug
- 316 Stainless Steel
- Hastelloy C-276
Electrical Connectors
- 1/2” NPT
- G 1/2”
- M20 x 1.5
Electromagnetic Interference Effect
- Meets All Relevant Requirements of EN 61326 & NAMUR NE-21
Enclosure Finish
- Polyurethane Paint
Enclosure, Body Material
- Cast Stainless Steel
- Low-Copper Aluminum
Environmental Protection
- IP66
- IP67
- IP68
- NEMA 4X
Fill Material
- Glycerin & Water
- Inert HaloCarbon
- Neobee M20
- Propylene Glycol & Water
- Silicone
- Syltherm XLT
Flange Material
- 316 Stainless Steel
- Carbon Steel
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150#
- 2” (DN 50) - 300#
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 16
- 2” (DN 50) - PN 25
- 2” (DN 50) - PN 40
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150#
- 3” (DN 80) - 300#
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 16
- 3” (DN 80) - PN 25
- 3” (DN 80) - PN 40
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150# (ANSI B16.5)
- 4” (DN 100) - 300# (ANSI B16.5)
Humidity
- 0 to 100 % Relative Humidity
Input Power
- 1-5 Vdc HART Low Power: 9-28 Vdc
- 4-20 mA HART: 10.5-42.4 Vdc
- FOUNDATION Fieldbus: 9-32 Vdc
- PROFIBUS: 9-32 Vdc
Mounting
- 150# ANSI
- 300# ANSI
- DN PN 10-40 Flange
- DN PN 40 Flange
NACE & NIST
- NACE MR-0103, MR-0175
NPT Connection
- 1/4” NPT Female
O-Ring Material
- Glass-Filled PTFE
Output
- 2.4 GHz DSSS
- 2-Wire 4-20 mA
- 3-Wire 1-5 Vdc
Overpressure & Static Pressure Limits
- Limit is Flange Rating or Sensor Rating, whichever is Lower
Power Supply Effect
- ± 0.005 % of Calibrated Span Per Volt
Pressure Range
- bar: -20.68 to 20.68
- inches WC: -1,000 to 1,000
- kPa: -2,068 to 2,068
- psig: -300 to 300
Pressure Type
- Differential
- Gauge
- Level
Process Temperature
- -40° to 121° C (-40° to 250° F)
- -75° to 205° C (-102° to 401° F)
Storage Temperature
- -46° to 110° C (-50° to 230° F)
Vibration Effect
- > ± 0.1 % of URL
Volumetric Displacement
- > 0.005”³ (0.08 cm³)
Wetted Materials
- 316L Stainless Steel
- Hastelloy C-276
- Tantalum
Documentation
Documentation
Data Sheets
Product Manuals
- Manual: Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems pdf 18.9 MB
- Quick Start Guide: 2051 Pressure Transmitter and 2051CF Series Flowmeter with PROFIBUS PA pdf 2.0 MB
- Quick Start Guide: 2051 Pressure Transmitter and 2051CF Series Flowmeter with WirelessHART Protocol pdf 1.9 MB
- Quick Start Guide: Rosemount 2051 Pressure Transmitter and 2051CF Series Flowmeter with 4-20 mA HART and 1-5 Vdc Low Power HART Protocol (Rev. 5 and 7) pdf 2.4 MB
Certificates & Approvals
Drawings & Schematics
- Type 1 Drawing: Rosemount 2051L Pressure Products 2D DXF dxf 6.7 MB
- Type 1 Drawing: Rosemount 2051L Pressure Products 2D PDF pdf 1.8 MB
- Type 1 Drawing: Rosemount 2051L Pressure Products 3D PDF pdf 1,002 KB
- Type 1 Drawing: Rosemount 2051L Pressure Products 3D SAT sat 6.7 MB
- Type 1 Drawing: Rosemount 2051L Pressure Products 3D STP stp 7.2 MB