Description
Make reliable pressure measurements in extreme conditions with the Rosemount 3051SAL Level Transmitter, a best-in-class solution that offers enhanced capabilities for pressurized and vented tank level measurements.
This transmitter is safety certified and engineered with advanced diagnostics for increased insight.
Designed to allow direct mounting, remote mounting, balanced systems and Tuned-System™ assemblies, this device can meet a variety of demands and process requirements for level applications.
Features- Integrated transmitter and direct mount seal in a single model number
- Variety of process connections including flanged, threaded, and hygienic remote seals
- Allows for direct mounting, remote mounting and balanced and tuned-systems to meet various application requirements
- Tuned-Systems can reduce temperature effects by 10-20% and improve response time by 80% vs. traditional installations
- Offers a variety of process connections including flanged, threaded and hygienic seals for application flexibility
- Welded-repairable construction allows the seal system to be repaired and all welded design provides a robust connection for challenging applications
- Scaled variable allows transmitter to output level units
- Remote display offers direct mount process connections with access to transmitter interface at grade
- SIL 2/3 certified to IEC 61508 (via 3rd party) and prior-use certificate of FMEDA data for safety installations
- Advanced diagnostics offer diagnostic coverage to detect electrical loop issues and abnormal process conditions
Configure
Specifications
Specifications
Brand
Accuracy
- ± 0.055 % of Span for Spans less than 10:1, ± [0.015 + 0.005(URL/Span)] % of Span
Alarm
- Custom Alarm & Saturation Signal Levels
- NAMUR Alarm & Saturation Signal Levels
Ambient Temperature Range
- -40° to 85° C (-40° to 185° F)
Applications
- Corrosive, Clogging, or Viscous Processes
- Extreme Hot & Cold Temperatures
- Hygienic Requirements
- Level
- Special Process Connections
Approvals & Certifications
- ATEX
- CSA
- FM
- IEC Ex
- INMETRO
- TIIS
Configuration
- 4-20 mA HART
- Electronic Remote Sensor (ERS) System
- HART Protocols
Damping Adjustment
- User Configurable from 0 to 60 seconds
Diaphragm Material
- 304L Stainless Steel
- 316L Stainless Steel
- Alloy 22 (Hastelloy)
- Carpenter 20 Stainless Steel
- Duplex 2507 Stainless Steel
- Hastelloy C-276
- Inconel
- Nickel 201
- Tantalum
- Titanium
- Zirconium 702
Display
- PlantWeb LCD Display
- Remote Mount LCD Display & Interface
Electrical Connectors
- 1/2” NPT Female
- G 1/2” Female
- M20 x 1.5
- PG13.5
Electromagnetic Interference Effect
- Meets All Relevant Requirements of EN 61326 & NAMUR NE-21
Enclosure Finish
- Polyurethane Paint
Enclosure, Body Material
- 316 Stainless Steel
- Aluminum
Environmental Protection
- IP66
- IP68
- NEMA 4X / IP66, 68
Fill Material
- DC 200, DC 704, or DC 705 Silicone Oil
- Glycerin & Water
- Inert
- Neobee M20
- Propylene Glycol & Water
- Syltherm XLT
- Ultra Therm 805
Flange Material
- 316L Stainless Steel
Flange Size - 1-1/2” (DN 40)
- 1-1/2” (DN 40) - 150#
- 1-1/2” (DN 40) - 1500#
- 1-1/2” (DN 40) - 2500#
- 1-1/2” (DN 40) - 300#
- 1-1/2” (DN 40) - 600#
- 1-1/2” (DN 40) - 900#
- 1-1/2” (DN 40) - JIS 10K
- 1-1/2” (DN 40) - JIS 20K
- 1-1/2” (DN 40) - JIS 40K
- 1-1/2” (DN 40) - PN 40
Flange Size - 1” (DN 25)
- 1” (DN 25) - 150#
- 1” (DN 25) - 1500#
- 1” (DN 25) - 2500#
- 1” (DN 25) - 300#
- 1” (DN 25) - 600#
- 1” (DN 25) - 900#
- 1” (DN 25) - JIS 10K
- 1” (DN 25) - JIS 20K
- 1” (DN 25) - JIS 40K
- 1” (DN 25) - PN 40
Flange Size - 1/2” (DN 15)
- 1/2” (DN 15) - 150#
- 1/2” (DN 15) - 1500#
- 1/2” (DN 15) - 2500#
- 1/2” (DN 15) - 300#
- 1/2” (DN 15) - 600#
- 1/2” (DN 15) - 900#
- 1/2” (DN 15) - JIS 10K
- 1/2” (DN 15) - JIS 20K
- 1/2” (DN 15) - JIS 40K
- 1/2” (DN 15) - PN 40
Flange Size - 2” (DN 50)
- 2” (DN 50) - 150#
- 2” (DN 50) - 1500#
- 2” (DN 50) - 2500#
- 2” (DN 50) - 300#
- 2” (DN 50) - 600#
- 2” (DN 50) - 900#
- 2” (DN 50) - JIS 10K
- 2” (DN 50) - JIS 20K
- 2” (DN 50) - JIS 40K
- 2” (DN 50) - PN 10
- 2” (DN 50) - PN 100
- 2” (DN 50) - PN 16
- 2” (DN 50) - PN 40
- 2” (DN 50) - PN 63
Flange Size - 3” (DN 80)
- 3” (DN 80) - 150#
- 3” (DN 80) - 1500#
- 3” (DN 80) - 2500#
- 3” (DN 80) - 300#
- 3” (DN 80) - 600#
- 3” (DN 80) - 900#
- 3” (DN 80) - JIS 10K
- 3” (DN 80) - JIS 20K
- 3” (DN 80) - JIS 40K
- 3” (DN 80) - PN 10
- 3” (DN 80) - PN 100
- 3” (DN 80) - PN 16
- 3” (DN 80) - PN 40
- 3” (DN 80) - PN 63
Flange Size - 3/4” (DN 20)
- 3/4” (DN 20) - 150#
- 3/4” (DN 20) - 1500#
- 3/4” (DN 20) - 2500#
- 3/4” (DN 20) - 300#
- 3/4” (DN 20) - 600#
- 3/4” (DN 20) - 900#
- 3/4” (DN 20) - JIS 10K
- 3/4” (DN 20) - JIS 20K
- 3/4” (DN 20) - JIS 40K
- 3/4” (DN 20) - PN 40
Flange Size - 4” (DN 100)
- 4” (DN 100) - 150#
- 4” (DN 100) - 1500#
- 4” (DN 100) - 2500#
- 4” (DN 100) - 300#
- 4” (DN 100) - 600#
- 4” (DN 100) - 900#
- 4” (DN 100) - JIS 10K
- 4” (DN 100) - JIS 20K
- 4” (DN 100) - JIS 40K
- 4” (DN 100) - PN 10
- 4” (DN 100) - PN 100
- 4” (DN 100) - PN 16
- 4” (DN 100) - PN 40
- 4” (DN 100) - PN 63
Humidity
- 0 to 100 % Relative Humidity
Input Power
- 4-20 mA HART: 16-42.4 Vdc
Mounting
- Direct Mount Seal System
NACE & NIST
- NACE MR-0103, MR-0175
NPT Connection
- 1” NPT Female
- 1/4” NPT Female
- 1-1/4” NPT Female
- 3/4” NPT Female
O-Ring Material
- Glass-Filled PTFE
- Graphite-Filled PTFE
Output
- 2-Wire 4-20 mA
Overpressure & Static Pressure Limits
- 0 psia to the Flange Rating or Sensor Rating, whichever is Lower
Power Supply Effect
- ± 0.005 % of Calibrated Span Per Volt
Pressure Range
- bar: -1.013 to 689.4
- inches WC: -393 to 1,000
- kPa: 101.3 to 68,948
- psi: -14.7 to 10,000
Pressure Type
- Absolute
- Gauge
Process Temperature
- -40° to 149° C (-40° to 300° F)
Storage Temperature
- -46° to 85° C (-50° to 185° F)
Tri-Clamp Connection
- 1-1/2” Sanitary Clamp
- 2” Sanitary Clamp
- 3” Sanitary Clamp
Vibration Effect
- > ± 0.1 % of URL
Volumetric Displacement
- > 0.005”³ (0.08 cm³)
Wetted Materials
- 304L Stainless Steel
- 316L Stainless Steel
- Alloy 22 (Hastelloy)
- Carpenter 20 Stainless Steel / Alloy 20 or Incoloy
- Duplex 2505 Stainless Steel
- Duplex 2507 Stainless Steel
- Hastelloy C-276
- Inconel
- Nickel
- Tantalum
- Titanium
- Zirconium 702
Documentation
Documentation
Product Manuals
- Manual Supplement: Rosemount 3051S Series Pressure Transmitter with FOUNDATION Fieldbus Protocol pdf 2.5 MB
- Manual: Rosemount 3051S Series Pressure Transmitter with HART Protocol pdf 10.2 MB
- Product Manual - Rosemount™ DP Level Transmitters and 1199 Diaphragm Seal Systems pdf 18.9 MB
- Quick Start Guide: Rosemount 3051S Series Pressure Transmitter and 3051SF Series Flowmeter with FOUNDATION Fieldbus Protocol pdf 2.0 MB
- Quick Start Guide: Rosemount 3051S Series Pressure Transmitter and 3051SF Series Flowmeter with HART Protocol pdf 3.3 MB
- Quick Start Guide: Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems pdf 706 KB
Certificates & Approvals
- FMEDA Report: Rosemount 3051S 4-20mA HART Pressure Transmitter pdf 399 KB
- FMEDA Report: Rosemount Remote Seals pdf 733 KB
- Product Certificate: Rosemount 3051S HART Advanced Diagnostics Pressure Transmitter, option code DA2 pdf 426 KB
- Product Certificate: Rosemount 3051S HART Diagnostics Pressure Transmitter, option code DA2 Sensor Software revision 5 or 6 pdf 999 KB
- Product Certificate: Rosemount 3051S Pressure Transmitter with Advanced HART Diagnostics Sensor Software Revision 5.0 and Above pdf 405 KB
- Product Data Sheet: Rosemount DP Level Transmitters and 1199 Seal Systems pdf 8.6 MB
- Product Safety Certificate: Rosemount 3051S 4-20mA HART Pressure Transmitter pdf 404 KB
Drawings & Schematics
- Type 1 Drawing: Rosemount 3051SAL Liquid Level Pressure Transmitter 2D PDF pdf 5.7 MB
- Type 1 Drawing: Rosemount 3051SAL Liquid Level Pressure Transmitter 3D PDF pdf 1.1 MB
- Type 1 Drawing: Rosemount 3051SAL Liquid Level Pressure Transmitter 3D SAT sat 8.4 MB
- Type 1 Drawing: Rosemount 3051SAL Liquid Level Pressure Transmitter 3D STP stp 8.9 MB